高精度阻抗分析儀

簡要描述:wk-6530B高精度阻抗分析儀 6500
功能 6505B 6510B 6515B 6520B 6530B 6550B 65120B 頻率范圍 20Hz–5MHz 20Hz–10MHz 20Hz–15MHz 20Hz–20MHz 20Hz–30MHz 20Hz–50MHz 20Hz–120MHz 基本精確度 0.05% 頻率精確度 ±0.005%

  • 廠商性質:生產廠家
  • 更新快照:2016-11-26
  • 訪  問  量:2109

詳細介紹

 

wk-6530B高精度阻抗分析儀介紹

量測參數

Z, Ø, L, C, R, Q, D, Y, G, B, X

輸出

10mV to 1V rms, 200uA to 20mA rms

顯示格式

串/并聯(lián)電路,或兩極式

wk-6530B高精度阻抗分析儀圖形分析模式

任選兩種參數依頻率, 驅動值及直流偏壓源掃描

wk-6530B電表模式

可當標準LCR電表使用

待測元件連接

可通過面板的BNC接頭來實現(xiàn)倆端,三端或四埠的連接以及可能的接地狀況.備有許多的可選附件以供不同的測試需要.

wk-6530B量測精度

消耗因素: ±0.0005(1+D*D2)

品質因素: ±0.05%(Q + 1/Q)

電容/電感/阻抗: ± 0.05

 

The 6500B series of Precision Impedance Analyzers provide precise and fast testing of components at frequencies up to 120 MHz. Basic measurement accuracy is ±0.05% making the instruments the best in the class.

The accuracy and versatility makes the precision analyzers the ideal choice for many different tasks and applications including passive component design, dielectric material characterisation and manufacturing test.

Engineers need to evaluate component characteristics at high frequencies with high levels of accuracy. The 65120B 120 MHz Precision Impedance Analyzer is therefore ideal for many demanding tasks, combining accuracy and ease of use at an affordable price. If a frequency range up to 120 MHz is not required then other models are available. The 6505B 5MHz instrument is the entry level model in the range.

 

 

High measurement accuracy

 

 

Capacitance, inductance and impedance basic accuracy is an excellent ±0.05%. Dissipation factor accuracy is ±0.0005 and the quality factor accuracy is ±0.05%.

 

 

Graphical sweep of components

 

 

 

 

 

 

 

Variable drive and bias levels

 

 

AC drive levels up to 1V or 20mA can be selected to evaluate components in realistic operating environments.
The /D1 DC bias option provides 0 to +40V dc bias voltage and 0 to +100mA dc bias current while the /D2 option provides -40V to +40V dc bias voltage.

 

 

External control

 

 

The GPIB interface is used to control the instrument and read back measured values for applications such as quality control or for archiving purposes.

An Ethernet interface similarly allows the instrument to be controlled and to send out data - allowing it to be integrated into many test environments.

 

 

Wide range of interfaces

 

 

An external monitor or projector may be connected to the instrument. The ability to provide a large screen display is invaluable in production environments or for teaching and training.

Instrument control from both a keyboard and mouse is available. Any keyboard or mouse, with either PS/2 or USB interfaces, can be simply connected to provide an alternative method of instrument control and operation.

 

 

Data storage and retrieval

 

 

All measurement and setup data can be stored using the Ethernet interface or a USB flash memory (supplied as standard).

 

 

Setup data

 

 

Up to 20 instrument setups may be stored locally for each mode.

 

 

Bin handling

 

 

The /B1 option (non-isolated 5V) or /B2 option (isolated 24V) signals are available through a 25-way D-type connector. 10 bins can be set using absolute or percentage limits.

 

 

Printer outputs

 

 

Hard copy printouts can be obtained in a number of ways including direct to an HP-PCL compatible graphics printer or Epson compatible text/ticket printer. A networked HP-PCL compatible printer may also be used via Ethernet connection.

 

 

Component connections

 

 

Four front panel BNC connectors permit three or four terminal connections with the screens at ground potential.
The 1J1011 component fixture, supplied as standard, ensures optimum performance when measuring a wide range of components of leaded components and devices.
1J1012 (2 Terminal) and 1J1014 (4 Terminal) fixtures allow connection to surface mount devices.

 

 

Protection against charged capacitors

 

 

High precision measuring instruments can be damaged by charged capacitors which can cause costly repairs and unacceptable downtime. All the models in the range incorporate protection against charged capacitors.

 

 

Comprehensive and precise component tests at higher frequencies

 

 

The 6500B series capabilities are best summarised by “Comprehensive and precise component tests at higher frequencies”. The instruments are the perfect solution for those who have demanding component measurement needs.

 

 

Technical Specifications:

 

 

Measurement Function

Capacitance (C)
Inductance (L)
Resistance (R)
Reactance (X)
Conductance (G)
Susceptance (B)
Dissipation Factor (D)
Quality Factor (Q)
Impedance (Z)
Admittance (Y)
Phase Angle (Ø)

Frequency Range

6505B 20Hz to 5MHz
6510B 20Hz to 10MHz
6515B 20Hz to 15MHz
6520B 20Hz to 20MHz
6530B 20Hz to 30MHz
6550B 20Hz to 50MHz
65120B 20Hz to 120MHz

Frequency step size 0.1 mHz
Accuracy of set frequency ±0.005"%

AC Drive Level

10 mV or 1V rms (varies with frequency)
200 µA to 20 mA rms (varies with frequency)

Measurement Speeds

4 speeds selectable
Up to 20 measurements per second for test frequencies ≥100 Hz

Accuracy

Dissipation factor - ±0.0005 (1+D2)
Quality factor - ±0.05 %( Q+1/Q)
Capacitance / Inductance / Impedance - ±0.05%
Accuracy varies with frequency, drive level and measured impedance

DC Bias Current (Option)

/D1 0 to +100mA dc bias current and 0 to +40V dc bias voltage
/D2 -40V to +40V dc bias voltage

Binning (Option)

10 bins with absolute and percentage limits
25 way d-type interface connector
/B1 (Non-isolated) Comon 0V Bin outputs 0 to 5V(normal) with >10mA current sink capability
/B2 (isolated) Comon 24V input outputs 0 to 24V with >10mA current source capability

 

 

General Data:

 

 

Input Specification

Power supply - Input voltage 90 V AC to 264 V AC (Autoranging)
Mains frequency 47 to 63 Hz

Display

8.4" VGA (650 x 480) color TFT with touch panel

Measurement Connections

Four front panel BNC connectors permit two, three or four terminal connections with the screens at ground potential.
1J1011 Component Fixture (supplied as standard) allows connection to leaded components and devices.

Printer

HP-PCL compatible graphics printing (local and network)
Centronics / parallel printer port, Epson compatible text/ticket printing (local)

Remote Trigger

Rear panel BNC with internal pull-up, operates on logic low or contact closure

GPIB Interface

External instrument control 24 pin IEEE 488 connector

USB Interface

Two Unversal Serial Bus (USB) interfaces
USB 1.1 compliant

VGA Interface

15-way D-type connector to drive an external monitor in addition to the internal screen

Network Interface

10/100-BASETX Ethernet controller
RJ45 connector

Keyboard Interface

Standard USB or PS/2 keyboard port. Instrument front panel remains active with keyboard plugged in

Mouse Interface

Standard USB or PS/2 mouse port
Touch screen remains enabled when the mouse is connected

 

產品咨詢

留言框

  • 產品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結果(填寫阿拉伯數字),如:三加四=7
蘇州賽秘爾電子科技有限公司
地址:蘇州高新區(qū)竹園路209號中國蘇州創(chuàng)業(yè)園4號樓6樓
郵箱:sales@saimr.com
傳真:86-0512-62519606
關注我們
歡迎您關注我們的微信公眾號了解更多信息:
歡迎您關注我們的微信公眾號
了解更多信息
放荡少妇交换超级乱| 冠希实干阿娇13分钟视频在线| 亚洲国产精品无码久久久老少 | 亚洲日韩激情无码一区| 日韩精品a片一区二区三区| 欧美精品久久久久a片色戒 | 亚洲乱码一区av春药高潮| 国产女人高潮叫床男人桶到爽| 欧美午夜一区二区福利视频| 日本体内she精高潮| 少妇人体metcn| 日本三级片在线观看| 亚洲熟妇色XXXXX欧美老妇| 少妇又紧又色又爽又刺激视频| 亚洲av片不卡无码久久| 久久精品AⅤ无码中文字字幕蜜桃| 天堂网在线观看| 日韩欧美高清dvd碟片| 欧美性xxxx极品少妇| 熟女人妻大叫粗大受不了| 囯产香蕉97碰碰碰视频在线观看| 亚洲精品一区二区另类图片| 最近高清无吗免费看| 免费国产AV在线观看| av无码免费播放| 天堂√中文最新版在线下载| 99久久久无码国产精品免费| 偿还HD韩国中文版| 性无码专区无码| 四虎成人精品在永久免费| 粗了大了 整进去好爽视频| 欧美日韩国产成人高清视频| 国产真实乱人偷精品视频免费| 无码精品一区二区三区在线| 尤物yw午夜国产精品视频| 日本一区二区三区免费更新不卡| 久久久九色综合亚洲成色777| 97av麻豆蜜桃一区二区| 国产盗摄xxxx视频xxxx| 中文乱码字慕人妻熟女人妻 | 黑人巨大精品欧美一区二区免费|